Glass spigots are stainless steel posts that clamp a glass panel at its base, so the railing has no top rail or vertical posts between panels. These are popular on decks, balconies, and pool fences because they keep the view open. Because each panel’s full load is carried by its two or three spigots together, a small mistake in anchoring, levelling, or clamping can cause a loose or unsafe railing.
This guide covers the full process in order: layout, mounting, setting the glass, alignment, and final inspection. It focuses on surface-mounted spigots, which bolt to the top of a slab or deck, or to the side of a slab edge or fascia, and includes a short note on core-drilled spigots. A fully adjustable spigot lets you fine-tune the glass angle during setup, but it cannot fix a bad base. Get the substrate right first.
Tools and Materials
Preparation prevents most installation errors. The following items are typically required:
- Measuring tape, chalk line, and laser level
- Hammer drill with masonry or concrete bits
- Torque wrench and hex keys
- Mechanical anchors (such as a 3/8″ x 3 3/4″ wedge anchor) or chemical anchors, as specified by the manufacturer
- Setting blocks, packers, and shims
- Glass suction lifters
- Spirit level and plumb bob
- Stainless steel glass railing spigots and tempered glass panels within the spigot’s rated thickness (Everoll’s spigots fit 10–12 mm glass)
- Core drill rig with a diamond bit (only for core-drilled spigots)
In coastal areas and other high-moisture locations, use 316 or duplex 2205 stainless steel for all hardware. Standard 304 can stain in salt air or from de-icing salt. Everoll’s spigots are made from SS2205 duplex stainless steel, which resists corrosion better than 304. Do not mix grades within one run.
Planning and Code Compliance
Before commencing drilling, ensure that the local building codes have been met. Under the National Building Code of Canada, guards must generally be at least 1,070 mm (42″) high. A lower minimum of 900 mm (about 36″) applies to guards inside a dwelling unit and to exterior guards serving a single dwelling unit where the walking surface is no more than 1,800 mm (about 5′11″) above the finished ground level. The glass has to be either tempered or laminated, while engineered drawings of the frameless system are required in most areas.
The surface must also be evaluated. There is a high bending load on the base through the spigot, so the concrete surface has to be in good condition and without any cracks. Blocking or the installation of a steel base structure under the mounting point in wood decks is necessary.
Step 1: Mark the Layout
Accurate layout determines the appearance of the whole run. Snap a chalk line along the railing edge, then mark spigot centres according to the glass panel width. Most panels use two spigots, positioned roughly 150 mm to 250 mm (about 6″ to 10″) in from each panel edge, though engineered specifications take priority.
Keep a consistent gap between adjacent panels, usually between 10 mm and 25 mm, and make sure the total run divides evenly, since a well planned glass railing layout on a deck prevents awkward cut panels and uneven spacing. Corners, stairs, and gates need separate calculations.
Step 2: Prepare the Mounting Surface
Surface-Mounted (Base-Plate) Installation
Base plates suit slabs, decks, and steel framing where coring is not practical.
- Position the spigot on the layout mark.
- Drill anchor holes at the specified edge distance, usually between 64 mm and 89 mm (2½″ to 3½″) from the slab edge.
- Install mechanical or chemical anchors to the manufacturer’s torque or cure requirements.
- On wood decks, use fasteners long enough to reach the framing or blocking, not just the deck boards, as specified by the engineer or manufacturer.
Anchor cure times matter. Chemical anchors usually need at least 24 hours before loading, and rushing this step weakens the connection.
Side-Wall (Fascia) Mount Installation
A side wall mounted spigot fixes to the face of a slab edge, fascia, or wall instead of the top surface, which suits balconies, staircases, and terrace walls. Mark the centres along the edge, confirm the edge is solid enough to carry the load, drill at the specified edge distance, and anchor each spigot. Use the adjustment screws to bring each one to plumb before the glass goes in.
Core-Drilled Note
If your design calls for core-drilled spigots set into concrete, drill each core to the specified diameter and depth (typically 100 mm to 150 mm), clear the dust, and check each hole for plumb. Set the sleeve in non-shrink grout, check verticality on two adjacent sides, and let the grout cure fully before loading.
Step 3: Install the Spigots
When it comes to core-drilled assemblies, position the spigot sleeve, and grout it using non-shrink grout, making sure the spigot is perfectly vertical from all angles. Check its verticality on two adjacent sides using a level; repeat after the grout starts to harden. Let the grout cure completely before you apply any loads.
With base-plate assemblies, mount the spigot onto the plate and tighten the fasteners in the cross configuration to avoid any tilting. Adjustable spigots enable small corrections to be made at this point; large discrepancies should be corrected at the substrate, not compensated for with the hardware.
The spigots in each run have to be at exactly the same height and at the same angle. To make sure that this requirement is met, draw a string line between the spigots before proceeding to the glass.
Step 4: Set the Glass Panels
- Panel installation usually requires at least two men per panel, and suction lifters rather than hand gripping should be used.
- Confirm the glass thickness falls within the spigot’s rated range (10–12 mm for Everoll’s spigots).
- Prior to lifting, inspect each panel for any chips, scratches, or damage along the edges, since such damages may cause later failure.
- Install the setting blocks or packers inside the spigot jaws, and then slowly lower the glass.
- Fit the packers or setting blocks inside the spigot jaws, then lower the glass slowly .The packers, typically made out of nylon or rubber materials, prevent direct contact between steel and glass, and ensure even distribution of the clamping forces. Improper choice of the packer’s thickness is the most frequent cause of loose and rattling panels.
- Support the panel while tightening the clamp screws snugly by hand. While the clamping screws are being snugly tightened by hand, support the panel.
- Centre the glass in the jaws with equal clearance on each side. The glass should be centrally positioned in the jaws, with equal clearance on each side.
Step 5: Align and Secure
After positioning the glass, use a spirit level to make sure each panel is plumbed correctly in relation to the glass face. The spigot can be adjusted using the built-in adjusting screws, one at a time. Make sure that the top edges of the glass are level.
Once the panel is properly aligned, secure the clamping screws according to the torque specifications recommended by the manufacturer. Do not over-tighten as this may cause the glass to crack and also crush the packers. If the screws are not tight enough, there may be movement.
Step 6: Fit Covers and Inspect
Fit the cover collars or base covers over the spigot bases before you set any glass panels. They hide the anchoring hardware and protect it from moisture, and they are much harder to fit once the glass is clamped in place. After the panels are installed, wipe the glass and metal surfaces to remove fingerprints, grout residue, and dust.
A final inspection should include:
- Pushing firmly on each panel to test stability
- Confirming uniform gaps between panels
- Checking all fasteners for correct torque
- Verifying guard height against the code requirement
- Inspecting glass edges for any damage from installation
Document the results, especially on commercial projects where inspection records may be required.
Common Stainless Steel Spigots Installation Mistakes
Several recurring errors affect the quality and safety of spigot railings.
- Inadequate substrate preparation: A fragile or cracked substrate does not have the ability to withstand the bending force exerted by spigots on the substrate. Prior to any drilling process, the substrate needs to be evaluated and fixed.
- Inconsistent spigot height: Even slight inconsistencies in spigot height become immediately apparent at the top edge of the glass panel. The string line helps ensure that the spigots are properly aligned prior to installing the glass.
- Wrong packers: Packers of an inappropriate thickness or type enable glass movement in jaws, causing the rattle noise. Packets must always correspond to the glass thickness and meet the manufacturer specifications for hardware.
- Skipped cure time: Premature loading of the anchor or grout, before the complete curing period, will lead to insufficient holding power and failure. Complete curing time as per the manufacturer must always be considered irrespective of the schedule of the project.
- Mixed hardware grades: Different types of grades of stainless steel or dissimilar metals in combination will result in galvanic corrosion. It can be prevented by using one single grade, with preference being given to 316 in a humid atmosphere.
Maintenance After Installation
Spigot railings require little maintenance. Regular inspections increase spigot railing lifespan. Check the clamping screws twice a year for looseness. Check the clamp screws twice a year and after freeze-thaw periods. Clean stainless steel using mild soap and water. Rinse stainless steel thoroughly in coastal environments. Rinse stainless steel to get rid of salt buildup. Replace worn or compressed packers promptly, since they keep the glass off the metal.
Need Stainless Steel Spigots for Your Next Installation? Contact Everoll Industries Ltd.
Everoll Industries Ltd supplies precision-engineered stainless steel spigots and glass railing hardware for residential and commercial projects across Canada. Each product is manufactured to consistent tolerances so that installers can achieve accurate alignment with fewer adjustments on site. The team provides technical guidance on hardware selection, load requirements, and installation planning to help projects meet code and perform over the long term. Contractors and homeowners can request product specifications, pricing, and bulk order support directly from the Everoll Industries Ltd. Contact Everoll Industries Ltd on 905 766 0080 or email us at info@everoll.com to discuss project requirements.
Frequently Asked Questions
- How do you install glass spigots?
Start by measuring and marking the spigot positions, then prepare the mounting surface. Drill the holes, secure the anchors, and check alignment before tightening each spigot firmly. Once the spigots are fixed, fit the glass panels, following the manufacturer’s instructions for gaskets, clamping, and final tightening. - How far apart should glass spigots be installed?
Spigot spacing depends on panel width and thickness, spigot design, railing height, expected loads, and manufacturer specifications, so no single distance applies. Measure the full layout and check the allowed spacing for your system. Everoll Industries Limited can confirm it. Call toll free 1 844 254 9614, call 905 766 0080, or email us at info@everoll.com. - How do you anchor glass spigots to concrete?
Check the concrete thickness, edge distances, and condition first, along with the anchor manufacturer’s requirements. Mark the mounting holes, drill them to the specified diameter and depth, and clean out the dust. Install compatible anchors according to instructions, secure the spigots, and verify alignment before fitting glass. - Can glass spigots be installed on a wooden deck?
Yes, glass spigots can be installed on a wooden deck, provided the deck can support the railing loads and the mounting system. Fasteners must reach the structural framing and should never rely on thin decking boards. Confirm the fastener type and the structural support before installation begins. - How do you level glass spigots during installation?
Use a spirit level or another measuring tool to check the alignment of each spigot and the line of the whole railing. Adjust only within the allowable adjustment range, then tighten the components following the manufacturer’s instructions. Recheck the level after tightening to confirm nothing has shifted. - What tools are needed to install glass railing spigots?
The usual tools include a tape measure, pencil or marker, spirit level, drill with compatible bits, anchor mounting tools, and the specified tightening tools. The exact list depends on the mounting surface and the spigot type. Everoll Industries Limited can advise on the right tools for your system. - Can glass spigots be installed on an uneven surface?
Some adjustable spigots can handle slight misalignment, but they cannot compensate for uneven or unstable surfaces. Resolve any surface or alignment problems before installation, using levelling or repair methods suited to the substrate. Make sure the finished railing meets all applicable safety requirements and local building codes. - What should you check before installing glass panels into spigots?
Before installing the panels, verify that the spigots are securely anchored, correctly aligned, and compatible with the specified glass thickness. Check that the correct gaskets and protective inserts are fitted and all fasteners are tightened to manufacturer specifications. Remember that tempered glass cannot be cut or drilled after tempering, so confirm dimensions first.